Matters needing attention for wiring harness maintenance of medical instruments and equipment

Date: 2021-03-30 Visited: 462

At present, the maintenance of medical equipment is a very complicated work, many medical institutions have equipment department, responsible for maintaining the safety and stability of equipment, but there are many problems that many equipment maintenance personnel do not understand or pay attention to. Here to everyone under the medical equipment wiring harness maintenance and maintenance.


The first point: meticulous daily maintenance, to ensure the normal operation of equipment is crucial.


Daily maintenance seems simple, but many times is not paid attention to, but also easy to ignore; But a lot of times big problems are compounded by small problems. To do with the clinical use of active cooperation, keep the surface of the instrument clean; Check whether the voltage and power supply are normal before use; During use, observe whether the function of the instrument is normal and fill in the use record. Develop good habits during routine maintenance to avoid damage.


Second point: equipment maintenance work, must be carefully handled, do not careless.


In case of equipment failure, information collection and preparation work should be done before maintenance. Including the model number, factory number, time of fault occurrence, abnormal sound when the fault occurs, whether there has been sudden power failure, whether the instrument has moved and other issues.


During maintenance, attention should be paid to the sequence of disassembly of medical equipment and do not force disassembly with brute force. Disassembled fastening screws, small pieces, etc., can not be conveniently placed, to be classified to avoid loss. After the completion of equipment maintenance, installation, and then in reverse order step by step to restore the original, no redundant accessories. The damaged parts should also be marked and restored to their original appearance after replacement, without any mistakes.


After the maintenance work is completed, clean the surface of the instrument, connect the power supply, to see if it can work normally. Calibrate the instrument to return to normal working state, and then hand it over to the user for trial to check whether the instrument is restored to the original working state, so as to avoid leaving hidden dangers. After cleaning the site, check whether there are missing tools, and fill in the maintenance log for future reference.


The protection engineer in maintenance should always pay attention to the protection work when maintaining the instrument, whether it is leakage or cross infection and other problems, should pay attention to the protection. Don't cause unnecessary injuries.


Third point: regular maintenance inspection, problems found as soon as possible, as soon as possible to solve.


Detailed preventive maintenance should include:


Appearance inspection: first of all, check whether the buttons, switches, joints and sockets of the instrument are loose and misplaced, whether the contact of plugs and sockets is oxidizing, rusting or poor contact, whether the power line is aging, whether the heat dissipation and exhaust air are normal, whether the connection of all kinds of grounding and pipe is good.


Cleaning and maintenance: it is to clean the electrical and mechanical parts of the surface and the internal parts of the instrument, including cleaning the filter screen and the relevant pipes, cleaning the relevant plugs and sockets of the instrument, to prevent bad contact, and lubricating the necessary mechanical parts.


Replacement of wearing parts: to have reached the service life and performance decline, substandard components or parts required to be replaced regularly as specified in the operation manual to timely replace, to prevent the possible expansion of the fault or cause the machine failure. In the case of insufficient battery charging, the relevant personnel should be urged to charge regularly, and all kinds of obvious and potential faults of the equipment should be eliminated.


Performance test calibration: test the voltage stability value of each DC power supply, the voltage value or waveform to be tested in the circuit, and make necessary calibration and adjustment according to the requirements of the manual, in order to ensure that the technical indicators of the instrument meet the standards, to ensure the quality of the instrument in medical diagnosis and treatment.


Safety check: 1. Check whether the frame is firm, whether the mechanical operation is normal, and whether the connecting parts are loose, fall off or rupture. 2. Check whether various leads, plugs and connectors are damaged, whether the grounding wire is firm, and whether the grounding resistance and leakage current are within the allowable limit.

Contact us

ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd

Hotline: +86-13929208661

Learn more

Feedback

© 2020-2021 ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd All Rights Reserved.   Powered by: ytclouds.net
主站蜘蛛池模板: 亚洲v无码专区日韩乱码不卡 | 欧美va天堂v国产综合 | 国产一区二区三区四区五区tv | 精品蜜臀久久久久99网站 | 精品二区中文字幕播放 | 亚洲aⅴ永久无码天 | 人人妻人人 | 国产无套视频在线观看aa在线 | 一区二区三区美女视频免费观看 | 国产动漫频道 | 国产99精华液单品榜推荐及分析 | 欧美精品无码喷 | 91极品18禁国产在线播放 | 国产欧美日韩精品丝袜高跟鞋 | 国产成人啪精品午夜在线观看 | 日韩亚洲欧美中文高清 | 精品久久久久久亚 | 国产精品乱码一区二区毛片 | 亚洲av无码专区亚洲a | 极品无码av国 | 丰满少妇又爽又紧又丰满在线观看 | 欧美在线不卡一区在 | 国产精品免费一区二区三区四 | 国产精品国内免费一区二区三区 | 国产亚洲精品合集久久久久 | 成人夜晚看片如何选择合适的影片 | 欧美丝袜高跟鞋一区二区 | 97久久久超国产精品 | 最新综合精品亚洲网址 | 果冻传媒在线观看九一制片厂 | 亚洲国产一成久久精品国产成人综合 | 欧美亚洲日韩在线观看 | 午夜精品久久久久久久无码软件 | 97狠狠操 | 国产黄大片在线观看画质优化 | 91成人午夜性a一级毛片 | 日本aaaa级| 在线精品亚洲一区二区动态图 | 国产亚洲这里只有精品 | 苍井空亚洲精品aa片在线播放 | 精品久久久 |